To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
The technical storage or access that is used exclusively for statistical purposes.
The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
2 Responses
I'm assuming that some or all of the paper facing has come off. The paper facing gives drywall rigidity. Without it, drywall sheets will simply crumble.
What you need to do depends on the severity of the problem. Two types of damage are; a single layer of paper came off with a brown paper remaining or all of the paper is missing with the gypsum core exposed.
1) Brown Paper Remaining – The paper will need priming before any joint compound can be applied. This will help stabilize the surface and prevent most of the bubbling that can happen if joint compound is applied without priming. Use a generous coat of Kilz Original Oil Base. Allow it to dry overnight before proceeding.
Now the entire surface needs 1-2 coats of joint compound. This will get it back to a flat surface again. Any and all major cracks or exposed core needs taping for reinforcement.
2) Gypsum Core Exposed – Technically, any drywall without its paper should be replaced with new. This isn't always possible or practical.
One way to deal with this is to prime (same as above) and use wide fiberglass mesh embedded in joint compound to stabilize the damaged drywall. Wide sheets of fiberglass mesh can be found at stucco supply houses. This is used with EIFS (Synthetic Stucco) systems and are 4-5 feet wide. After embedding apply another coat of joint compound.
You will have to decide just how bad it is and what direction to take. Both of these techniques can be combined to suit your own unique situation.
I'm assuming that some or all of the paper facing has come off. The paper facing gives drywall rigidity. Without it, drywall sheets will simply crumble.
What you need to do depends on the severity of the problem. Two types of damage are; a single layer of paper came off with a brown paper remaining or all of the paper is missing with the gypsum core exposed.
1) Brown Paper Remaining – The paper will need priming before any joint compound can be applied. This will help stabilize the surface and prevent most of the bubbling that can happen if joint compound is applied without priming. Use a generous coat of Kilz Original Oil Base. Allow it to dry overnight before proceeding.
Now the entire surface needs 1-2 coats of joint compound. This will get it back to a flat surface again. Any and all major cracks or exposed core needs taping for reinforcement.
2) Gypsum Core Exposed – Technically, any drywall without its paper should be replaced with new. This isn't always possible or practical.
One way to deal with this is to prime (same as above) and use wide fiberglass mesh embedded in joint compound to stabilize the damaged drywall. Wide sheets of fiberglass mesh can be found at stucco supply houses. This is used with EIFS (Synthetic Stucco) systems and are 4-5 feet wide. After embedding apply another coat of joint compound.
You will have to decide just how bad it is and what direction to take. Both of these techniques can be combined to suit your own unique situation.